E35Fault · Power sectionUsually repairable
Kinetix 6000 E35: DriveUndervoltage Fault (Precharge Fault)
Also shown as: Shown as E35 on the seven-segment display
What E35 means
The converter precharge cycle failed, so the DC bus did not charge correctly.
Symptoms
The drive will not become ready after main power is applied.
Is it repairable?
Yes: precharge circuits are repairable.
Common causes
- Low AC input voltage
- Failed precharge circuit inside the IAM
Safe checks
- 1Measure the AC input voltage on all three phases
Drives hold dangerous voltage after power-off. Checks should only be done by qualified personnel, with power isolated and the DC link discharged.
Reviewed by AutomIQ repair technicians. Code and name from the Kinetix 6000 Multi-axis Servo Drives User Manual.