F30002Fault · Drive
SINAMICS S210 F30002: Drive DC Link Overvoltage
What F30002 means
The DC link (DC bus) voltage inside the S210 rose above its trip level, usually because a braking motor fed energy back faster than the converter could get rid of it.
Symptoms
Trips while the axis is slowing down, on fast stops, or while a vertical axis is lowered.
Is it repairable?
Often a setting or braking-resistor issue; repairable when the converter's braking circuit or voltage measurement has failed.
Common causes
- Deceleration too fast for the load
- Braking resistor missing, undersized or open
- Supply voltage too high or spiking
- A supply phase interrupted
Safe checks
- 1Note whether it always trips during braking
- 2Check the braking resistor (internal or external) and its wiring
- 3Measure the incoming line voltage
Drives hold dangerous voltage after power-off. Checks should only be done by qualified personnel, with power isolated and the DC link discharged.