A.10Alarm · Power sectionUsually repairable
Yaskawa SGDH A.10: Overcurrent Or Heat Sink Overheated
What A.10 means
Overcurrent flowed through the SERVOPACK's power transistors (IGBT), or its heat sink overheated.
Symptoms
Alarm at servo ON or during acceleration; may not reset.
Is it repairable?
Yes: IGBT and power stage repair is common on SGDH units.
Common causes
- Short or ground fault in the motor or cable
- Failed IGBT
- Heat sink overheating from a failed fan or blocked airflow
- Wrong motor connection
Safe checks
- 1With power off, megger the motor and cable
- 2Check the U, V, W wiring
- 3Check the fan and airflow
Drives hold dangerous voltage after power-off. Checks should only be done by qualified personnel, with power isolated and the DC link discharged.
Reviewed by AutomIQ repair technicians. Code and name from the Yaskawa SGDH SERVOPACK manual.