Repairs in Canada & USA · Parts shipped worldwide

info@automiqautomation.ca+1 343-507-0006BrochureLine CardFree evaluation on every repair
AutomIQ Automation & Drive Services
AboutContact
Request a QuoteRequest a Repair
AutomIQ Automation & Drive Services
Home

Shop by category

Servo DrivesServo MotorsEncodersHMIs & Operator PanelsPLCs & I/OPower SuppliesCNC ControlsLegacy & ObsoleteSensorsSafety EquipmentGearboxesPneumatics & HydraulicsOther PartsAll parts

Shop by manufacturer

SiemensAllen-BradleyRexroth IndramatFanucYaskawaMitsubishi ElectricABBSchneider ElectricOmronBeckhoffKollmorgenLenzeAll manufacturers A–Z
View all shop parts
Servo Drive RepairServo Motor RepairEncoder Repair & AlignmentHMI RepairPLC RepairPower Supply RepairCNC Control RepairExchange Program
View all repair services
SiemensAllen-BradleyRexroth IndramatFanucYaskawaMitsubishi ElectricABBSchneider ElectricOmronBeckhoffLenzeKollmorgenBaldorParkerMoogPro-face
View all brands
AutomotivePackagingPlastics & ThermoformingFood & BeverageMetalworking & CNCPrintingPharmaceuticalMaterial Handling
View all industries

Learn

Fault Code LibraryBlog & GuidesGlossaryFAQs

Tools

Downtime Cost CalculatorRepair or Replace AdvisorPart Number CheckerModel Code Decoder

Working With Us

Repair ProcessHow to Ship Us a UnitService AreasInternational OrdersOn-site ServiceSell Your SurplusWarranty, Terms & Privacy
View all resources
AboutContact
Request a RepairRequest a Quote
  1. Home
  2. Fault Codes
  3. PowerFlex 525
AB

PowerFlex 525 Fault Codes & Alarms

All 47 codes. PowerFlex 523 and 525 fault codes F002 to F127. Type 1 faults can reset automatically; Type 2 faults need a manual reset.

PowerFlex 525 fault codes
CodeNameAreaGuide
F002Auxiliary InputInputs / external
F003Power LossPower section
F004UnderVoltagePower sectionFull guide
F005OverVoltagePower sectionFull guide
F006Motor StalledMotor / load
F007Motor OverloadMotor / loadFull guide
F008Heatsink OvrTmpThermalFull guide
F009CC OvrTmpThermal
F012HW OverCurrentPower sectionFull guide
F013Ground FaultPower sectionFull guide
F015Load LossMotor / load
F021Output Ph LossMotor / loadFull guide
F029Analog In LossInputs / external
F033Auto Rstrt TriesParameters / setup
F038Phase U to GndPower sectionFull guide
F039Phase V to GndPower section
F040Phase W to GndPower section
F041Phase UV ShortPower sectionFull guide
F042Phase UW ShortPower section
F043Phase VW ShortPower section
F048Params DefaultedParameters / setup
F059Safety OpenInputs / external
F063SW OverCurrentMotor / load
F064Drive OverloadPower sectionFull guide
F070Power UnitPower sectionFull guide
F071DSI Net LossCommunication
F072Opt Net LossCommunication
F073EN Net LossCommunication
F080Autotune FailureParameters / setup
F081DSI Comm LossCommunication
F082Opt Comm LossCommunication
F083EN Comm LossCommunication
F091Encoder LossEncoder / feedbackFull guide
F094Function LossInputs / external
F100Parameter ChksumControl module
F101External StorageControl module
F105C Connect ErrControl module
F106Incompat C-PControl module
F107Replaced C-PControl module
F109Mismatch C-PControl module
F110Keypad MembraneControl module
F111Safety HardwareControl module
F114uC FailureControl moduleFull guide
F122I/O Board FailControl moduleFull guide
F125Flash Update ReqControl module
F126NonRecoverablErrControl module
F127DSIFlashUpdatReqControl module
Showing 47 of 47 codes

Codes and names from the PowerFlex 520-Series Adjustable Frequency AC Drive User Manual. Guides written and reviewed by AutomIQ repair technicians.

PowerFlex 525 repair

PowerFlex drive faulted?

  • Free evaluation and written quote
  • Tested on our own test jigs
  • Exchange units when in stock
Send this unit in Ask a technician

PowerFlex 525 fault guides

  • F004UnderVoltage
  • F005OverVoltage
  • F007Motor Overload
  • F008Heatsink OvrTmp
  • F012HW OverCurrent
  • F013Ground Fault
  • F021Output Ph Loss
  • F038Phase U to Gnd
All brands

Drives hold dangerous voltage after power-off. Checks should only be done by qualified personnel, with power isolated and the DC link discharged.

Machine down? Let's get it running again.

Request a Repair +1 343-507-0006
Calls & WhatsApp
+1 343-507-0006
Turnaround
24–72 hr typical
Exchange units
1–2 business days once yours arrives
Fault codes
2,364 explained
AutomIQ Automation & Drive Services

Servo drive, motor and industrial electronics repair for Canada and the USA.

  • info@automiqautomation.ca
  • +1 343-507-0006
  • 1301 Matheson Blvd E, Mississauga, ON L4W 1R1 Directions

Repair

  • Servo Drive Repair
  • Servo Motor Repair
  • Encoder Repair
  • CNC Control Repair
  • Exchange Program
  • On-site Service

Shop Parts

  • Servo Drives
  • Servo Motors
  • PLCs & I/O
  • CNC Controls
  • Legacy & Obsolete
  • Sell Your Surplus

Brands

  • Siemens
  • Rexroth Indramat
  • Allen-Bradley
  • Fanuc
  • All brands

Company

  • Fault Code Library
  • Industries
  • Service Areas
  • International Orders
  • About
  • Contact
  • Request a Quote

© 2026 AutomIQ Automation & Drive Services

PrivacyTermsWarrantySitemapBrochureLine CardUSA site

AutomIQ Automation & Drive Services is an independent repair and surplus parts provider. We are not affiliated with, authorized by, or endorsed by any manufacturer named on this site, and we are not an authorized distributor or service centre unless stated. All brand names, logos, model numbers and trademarks belong to their respective owners and are used only to identify compatible equipment. New and surplus parts sold by us may not include the manufacturer's warranty; our own warranty applies as stated. Product images may be representative.